Group Boiler Whine
Group Boiler Whine
I was getting a high pitched whine from the group boiler whenever the heating element kicked in and it was nearing the set temperature. I was also getting some water dripping at the same time from either the group head or the 3 way valve outlet. I tried back-flushing alot, also with Cafiza and was able to make it intermittent but the noise and dripping came back. This was a loud whine you could hear two rooms away. I decided to check the expansion valve setting because it seemed to me that on heating the pressure might get high enough to force some water past the 3 way valve and create the whine. So I followed the procedure on adjusting the 3 way valve and found it was cranked tight! I loosened it nearly 3 full turns to get it to drip at 12.5 bar. Glory be - the whine stopped. Thanks again to Charles for the information on this site that helped me fix this. 

- chas
- Vivaldi Dreamer
- Posts: 3057
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
I remember some forum members describing something like this a year or so ago. They called Chris Coffee and were told to unscrew the expansion valve 2-3 turns and this fixed the issue in all cases.
It seems intuitively wrong but you can't knock success!
It seems intuitively wrong but you can't knock success!
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
- chas
- Vivaldi Dreamer
- Posts: 3057
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
The expansion valve was way tight on my VII when I received it. I had to unscrew quite a bit also to get it to open at 12.5bar. With it properly adjusted I get very little dripping. Perhaps a few drops after I pull a shot. However, before the adjustment I would get some drips every time the boiler cycled.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
Here is a link to the video (I hope I did this right):
http://karatevid.com/clips/noiseV2.wmv
The noise is kind of faint on the video. It sure sounds like the fan to me.
-Joe
http://karatevid.com/clips/noiseV2.wmv
The noise is kind of faint on the video. It sure sounds like the fan to me.
-Joe
Niko wrote:can you post a video with sound?
we can listen for it and tell you...
So after replacing the pump, and attempting to calibrate the expansion valve per Chas' instructions, I got the same whine whenever the boiler would refill.
Anyhow, now I am at this situation:
At it's current position (or tighter), it does not drip, but will whine when refilling. If I go a 1/4 turn looser, the whining stops, but a cup under it reveals that within an hour or so, about 2 ounces has dripped (just sitting at idle).
I guess my concerns are:
1. My calibration is out the window, so should I try to recalibrate? If not, is there any risk or consequences?
2. If I leave it in the position where it does drip, but does not whine, is there any risk or consequences?
3. Seeing as how I have had numerous brass shavings throughout my system, does it make sense to take apart the expansion valve? If so, anything I need to do other than unscrew it (loosen it)?
Anyhow, now I am at this situation:
At it's current position (or tighter), it does not drip, but will whine when refilling. If I go a 1/4 turn looser, the whining stops, but a cup under it reveals that within an hour or so, about 2 ounces has dripped (just sitting at idle).
I guess my concerns are:
1. My calibration is out the window, so should I try to recalibrate? If not, is there any risk or consequences?
2. If I leave it in the position where it does drip, but does not whine, is there any risk or consequences?
3. Seeing as how I have had numerous brass shavings throughout my system, does it make sense to take apart the expansion valve? If so, anything I need to do other than unscrew it (loosen it)?
Mine leaks as we speak...
Not sure why but it constantly drips whenever the group light flashes to indicate that the element is on. There was a time when I would make some adjustments to stop the leaking but it hasn't bothered me enough to mess with it. My old S1 does not leak at all but that machine is not plumbed in the same room.
As for that whine, I'd like to hear it...
can you post a video with sound? Maybe mine does it too but it never dawned on me. It does sound like your adjustments are either too far North or South.
Do you have any ideas, Chas?
Not sure why but it constantly drips whenever the group light flashes to indicate that the element is on. There was a time when I would make some adjustments to stop the leaking but it hasn't bothered me enough to mess with it. My old S1 does not leak at all but that machine is not plumbed in the same room.
As for that whine, I'd like to hear it...
can you post a video with sound? Maybe mine does it too but it never dawned on me. It does sound like your adjustments are either too far North or South.
Do you have any ideas, Chas?
- chas
- Vivaldi Dreamer
- Posts: 3057
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
There should be a thread here somewhere on this unless it was discussed during the missing 6 months in 2006. Whoever had that happen first called Chris Tech Support and was told to give the expansion valve about 1 1/2 turns. However, I don't remember which way you are supposed to turn it, but that seemed to be the definitive fix.
For those that have never removed the expansion valve, you may want to check it. It is a pretty basic design. Inside the valve is just a spring with a rubber disk attached to the end. The spring pushes this disk up against the end of a pipe that is a little smaller in diameter than the diameter of the rubber disk. It is possible to get some crud between the end of the pipe and the rubber disk or the rubber disk might be hitting the pipe off center. Cleaning this out and checking the state of the rubber disk is worthwhile.
The caveat is that it takes a bit of effort to screw the valve back on because you have to push up hard against the spring while getting it threaded back on. This pushing is done at a fairly awkward angle so it make take a few attempts to get it started. Not a real big deal.
Then any time you take that valve apart you have to readjust the release pressure on the valve (12.5 bar) and then readjust the group pressure. This is documented on the S1 site. Just use the "Go to S1 Web Site" at the top of this page.
For those that have never removed the expansion valve, you may want to check it. It is a pretty basic design. Inside the valve is just a spring with a rubber disk attached to the end. The spring pushes this disk up against the end of a pipe that is a little smaller in diameter than the diameter of the rubber disk. It is possible to get some crud between the end of the pipe and the rubber disk or the rubber disk might be hitting the pipe off center. Cleaning this out and checking the state of the rubber disk is worthwhile.
The caveat is that it takes a bit of effort to screw the valve back on because you have to push up hard against the spring while getting it threaded back on. This pushing is done at a fairly awkward angle so it make take a few attempts to get it started. Not a real big deal.
Then any time you take that valve apart you have to readjust the release pressure on the valve (12.5 bar) and then readjust the group pressure. This is documented on the S1 site. Just use the "Go to S1 Web Site" at the top of this page.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
I had already taken it apart, and really could not find anything amiss.
Well it sounds like I have a worn seat (the rubber disc inside the expansion valve), since mine leaks all the time and should only drip or leak when group boiler is refilling. This is all according to Jason at Chris' coffee.
The problem is that literally the point at which it stops whining is the point at which it starts leaking, so there is no happy medium. Should have the disc this week, and will report back. I am pretty sure this will fix it, and of course I want this fixed before I sell it.
Well it sounds like I have a worn seat (the rubber disc inside the expansion valve), since mine leaks all the time and should only drip or leak when group boiler is refilling. This is all according to Jason at Chris' coffee.
The problem is that literally the point at which it stops whining is the point at which it starts leaking, so there is no happy medium. Should have the disc this week, and will report back. I am pretty sure this will fix it, and of course I want this fixed before I sell it.