I came back to my S1 after 18 months apart (sitting idle, unplugged). It seems fine, except the hot water port just give a small amount, then a trickel. Plenty of steam from the wand. I removed to "head" part (w/ the screen), no help.
Video:
https://photos.app.goo.gl/GiP6sBFipRshkmgK8
Any ideas what to check?
Limited water from outlet, plenty of steam
- chas
- Vivaldi Dreamer
- Posts: 3056
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Limited water from outlet, plenty of steam
Based on the amount of steam coming out instead of hot water, it seems possible that the water level in your steam boiler is too low. Try loosening the nut that keeps the water level probe in place, pull the probe up about 1/4" to 1/3", then retighten the nut.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
Re: Limited water from outlet, plenty of steam
Thanks. Is there a set of schematics/instructions I should check out?
- chas
- Vivaldi Dreamer
- Posts: 3056
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Limited water from outlet, plenty of steam
I have little doubt that LaSpaziale has schematics for this device but they have never shared them with the masses.
However, many people have had issues with the water level sensor over the years. You should be able to find some of these threads using the Forum's search feature.
However, many people have had issues with the water level sensor over the years. You should be able to find some of these threads using the Forum's search feature.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
Re: Limited water from outlet, plenty of steam
This is the closest I have seen: https://www.manualslib.com/manual/74928 ... =22#manual
It is also linked here: http://s1cafe.com/s1v2/
It is also linked here: http://s1cafe.com/s1v2/
- chas
- Vivaldi Dreamer
- Posts: 3056
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Limited water from outlet, plenty of steam
A couple of comments about that water flow schematic:
1) I don't think that's what the poster is looking for.
2) That is not a LaSpaziale approved document. I created that drawing by taking all the covers off and manually tracing the path of the water lines. I think it's reasonably accurate but I wouldn't give it 100%.
1) I don't think that's what the poster is looking for.
2) That is not a LaSpaziale approved document. I created that drawing by taking all the covers off and manually tracing the path of the water lines. I think it's reasonably accurate but I wouldn't give it 100%.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B