- dream inlet valve.JPG (27.95 KiB) Viewed 6234 times
The amount of debris that could cause this is almost microscopic. I went through a series of this, where it would stay ok for about 6 weeks and then I would have to clean again. Finally, instead of just removing the plunger and cleaning under the seat (I used a magnifying glass, and a Q tip with alcohol to get it clean, I removed the valve body. The inlet entrance has a tiny mesh filter, and a washer. I noted that when fitted, the washer and filter were too thin to completely cover the opening to the valve body. So in effect, debris was bypassing the mesh filter and getting under the seat. I bought a Parker solenoid valve to replace it, and it had a smaller inlet opening and that allowed the filter to do its job. I'm talking about parts 1131 and 2284 on the parts diagram. They fit loosely into the inlet and allow bypass to occur.
BTW. I noticed that when the boiler fills with the new valve, the indicated pressure is about 3 bar. With the old valve with the bigger gap, it was about 6 bar. I'm sure the higher pressure was helping force debris into seat.