Steam Boiler slow to raise pressure
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Steam Boiler slow to raise pressure
Normally once a certain point is reached the steam boiler pressure rises fairly quickly however recently it has become quite slow to reach pressure.
Once it does however there is ample steam.
Once it does however there is ample steam.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Re: Steam Boiler slow to raise pressure
Scale on the heating-element could be the culprit
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
frachlitz wrote:Scale on the heating-element could be the culprit
Good thought. Would scale buildup cause a gradual slowing of pressure rise rather than an abrupt slowing?
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Better culprit;
Opened steam boiler. Heating element sheath near top plate split exposing heating element ant white color internal packing. Virtually no scaling noted anywhere.
Also splitting seen in spiral looping. Maybe thats why it is slower to reach pressure.
Opened steam boiler. Heating element sheath near top plate split exposing heating element ant white color internal packing. Virtually no scaling noted anywhere.
Also splitting seen in spiral looping. Maybe thats why it is slower to reach pressure.
Last edited by steve96822 on Mon Nov 16, 2015 3:44 am, edited 1 time in total.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Source for 220V S1 heating element anyone??? Gasket is likely same as 110 volt model
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Suggestions on best way to remove nuts that hold heating element in place??
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
One more question if I may;
With wires from steam boiler disconnected can I use machine just for espresso ? Even if steam boiler top plate is off?
With wires from steam boiler disconnected can I use machine just for espresso ? Even if steam boiler top plate is off?
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
- chas
- Vivaldi Dreamer
- Posts: 3050
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Steam Boiler slow to raise pressure
Use a metric wrench to remove the nuts on the top side of the boiler lid, then just just the heater element through. BTW: I've never seen an element blow up from an internal explosion. It must have leaked some water inside which flashed into steam and blew a hole in the side. If this had happened below the water line, it probably would have blown a fuse or tripped your home circuit breaker.
Sure you can run the machine with the steam boiler wires not attached. HOWEVER, you'll also need to press the Boiler button to electronically turn the boiler off. Otherwise, the controller knows it has commanded the Boiler to turn on and when the temp sensor fails to hit 60C within 5 minutes the machine will throw an alarm.
Sure you can run the machine with the steam boiler wires not attached. HOWEVER, you'll also need to press the Boiler button to electronically turn the boiler off. Otherwise, the controller knows it has commanded the Boiler to turn on and when the temp sensor fails to hit 60C within 5 minutes the machine will throw an alarm.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Thanks.
When I turn on the S1 will the steam boiler water start refilling? What I need to know is if I need to secure the steam boiler top?
Actually much of the coil at water level has midline splitting and shows the white packing material. Strange indeed.
Any sources you know of for a 220V element?
When I turn on the S1 will the steam boiler water start refilling? What I need to know is if I need to secure the steam boiler top?
Actually much of the coil at water level has midline splitting and shows the white packing material. Strange indeed.
Any sources you know of for a 220V element?
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Just tried to use S1 , powered on and immediately steam boiler began to refill. Shut off boiler but coffee boiler never got hot.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
- chas
- Vivaldi Dreamer
- Posts: 3050
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Steam Boiler slow to raise pressure
That's a good point. In case you forget to turn the Boiler Off you should probably put the lid back on. On the other hand, I am not sure if the refill function is also disabled when you press the Boiler button or not. Better play it safe.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Boiler off button did stop the filling but coffee boiler never got hot
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
- chas
- Vivaldi Dreamer
- Posts: 3050
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Steam Boiler slow to raise pressure
You must have another problem then because there is no interaction that I am aware of between the two boilers other than that the steam boiler does not start heating until the group boiler is up to temp. After pressing the Boiler button the group boiler should continue functioning normally.steve96822 wrote:Boiler off button did stop the filling but coffee boiler never got hot
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Before I disconnected the steam boiler wiring all worked fine. I suspect the board needs to detect everything connected at least electrically.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Solved coffee boiler; one of the leads got disconnected to heating element. Now working
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
- chas
- Vivaldi Dreamer
- Posts: 3050
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Steam Boiler slow to raise pressure
Now that makes sense. The water level probe and the temp sensor have connections to the controller board but not the heater elements.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
I may try a thred file.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
- chas
- Vivaldi Dreamer
- Posts: 3050
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Steam Boiler slow to raise pressure
I Googled A2 80 but not a lot of help. All that really means is that it's a metric stainless steel bolt made of 304 type stainless steel. I guess you need to find a local supplier of metric SS bolts, take one with you, and find a thread pitch and length match. If you have a thread chaser that can fix it that's great. If not, it's got to be cheaper to find a new bolt that to purchase a thread chaser.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
- chas
- Vivaldi Dreamer
- Posts: 3050
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Steam Boiler slow to raise pressure
Here is the size to get in A2 stainless steel:
M6 x 1.0 x 12M Hex Tap Bolt
M6 means the shaft diameter is 6mm wide
1.0 means the thread pitch is one turn per millimeter
12M means the bolt length is 12mm
If you can't find A2 SS then 18-8 will do. The type of stainless steel is less important than the fact it MUST be stainless steel.
M6 x 1.0 x 12M Hex Tap Bolt
M6 means the shaft diameter is 6mm wide
1.0 means the thread pitch is one turn per millimeter
12M means the bolt length is 12mm
If you can't find A2 SS then 18-8 will do. The type of stainless steel is less important than the fact it MUST be stainless steel.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Heres another question; The plastic cap of the thermostat came off (brittle) I can glue it back together if it will not make a difference.
See pics
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
http://www.ebay.com/itm/20PCS-M6-Series ... 76ih-t-Q8w
A2 = 304 Stainless steel
Vivaldi Steam Boiler top plate bolts
These should fit
A2 = 304 Stainless steel
Vivaldi Steam Boiler top plate bolts
These should fit
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Actually there is big time failure below water line but it still worked. any stainless steel heating elements available?
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Re: Steam Boiler slow to raise pressure
That's incredible that it happened, and then continued to work.
John
Mini Vivaldi, EPC-8, SJ, Steel Burr Vario
Behmor, Modded Poppery
Coffee Stuff
Mini Vivaldi, EPC-8, SJ, Steel Burr Vario
Behmor, Modded Poppery
Coffee Stuff
- chas
- Vivaldi Dreamer
- Posts: 3050
- Joined: Wed Jun 02, 2004 11:52 pm
- Location: Central Maryland
- Contact:
Re: Steam Boiler slow to raise pressure
I think you're stuck with getting another copper one. On the plus side I've never heard of this happening before so odds are it won't happen to you again.
Chas
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
LM GS/3 & LaSpaziale Dream v 1.25 (US 120V)
Mazzer Kony E, Customized Rocky
Hottop P/B
-
- God Shot
- Posts: 135
- Joined: Tue May 30, 2006 5:08 pm
- Location: US/Asia
Re: Steam Boiler slow to raise pressure
Remember chemistry? When you add solute to water you raise the boiling point. I think the white substance was messing with the boiling point/ water properties in the boiler. My new heating element works great with the old tem sensor..
The steam boiler gasket took hours to dig out, then clean channel. That oem gasket turns into concrete and basically fuses with the boiler.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)