No water from hot water tap

Post by steve96822 »

I hear solenoid click but only a few drops come out. (boiler red light is steady and steam pressure very good)
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
JohnB

Re: No water from hot water tap

Post by JohnB »

If the steam is working I'd open up the valve assy & check for blockage. Also drop the screen on the water tap. Ever descaled the boiler?
steve96822
God Shot
Posts: 135
Joined: Tue May 30, 2006 5:08 pm
Location: US/Asia

Re: No water from hot water tap

Post by steve96822 »

I have hardly used the hot water tap. Never descaled yet.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
steve96822
God Shot
Posts: 135
Joined: Tue May 30, 2006 5:08 pm
Location: US/Asia

Re: No water from hot water tap

Post by steve96822 »

today after taking the cup warmer cover off and inspecting I fired up and magically everything works 100%.

Perhaps not using the electrovalve for a long time made it stick
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
JohnB

Re: No water from hot water tap

Post by JohnB »

steve96822 wrote:today after taking the cup warmer cover off and inspecting I fired up and magically everything works 100%.

Perhaps not using the electrovalve for a long time made it stick
That's what I was thinking after reading your previous post. If you seldom use the water tap I'd definitely consider draining the boiler if you plan to use that water in drinks. We use ours daily & I still drain the boiler once a month. Easily done with the drain plug underneath but you might have to elevate the machine to get a pan under there if you are using the stock "feet".
steve96822
God Shot
Posts: 135
Joined: Tue May 30, 2006 5:08 pm
Location: US/Asia

Re: No water from hot water tap

Post by steve96822 »

Thanks, I will drain boiler.

So the moral of the story; if something doesn't work on an S1, sleep one night then try again.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
steve96822
God Shot
Posts: 135
Joined: Tue May 30, 2006 5:08 pm
Location: US/Asia

Re: No water from hot water tap

Post by steve96822 »

A followup; Upon looking inside housing and inside boiler I discovered an occluded outlet. Mineral deposit was the culprit and easily cleared blockage, sort of like doing an embolectomy.


As an idea, a possible way to clear a mineral obstruction would be t open hot water valve and use a wound guitar string (like low E) to insert in hot water outlet and probe distally. Would need to take safety measure to prevent getting burned.Hands, arms, face, body.
S1 V1 220volt
Mazzer mini
Ascaso Innova doserless
Simonelli Oscar
Olympia Cremina
Faema lever antique(working)
MDL
Barista
Posts: 329
Joined: Sat Apr 07, 2007 11:29 am
Location: San Diego

Re: No water from hot water tap

Post by MDL »

I found that the solenoid valve for the hot water developed scale when I was not regularly pulling hot water. I had to open the valve and clean with white vinegar. After that I made it a practice to pull some water each morning and I have not had subsequent scale issues. As an added benefit this helps to bring fresh water into the steam boiler to help slow the rate of scale build up.
JohnB

Re: No water from hot water tap

Post by JohnB »

Did you wait 5 years to look in the boiler or just took that long to post the followup? :lol: My V2 is long gone but I do use the hot water function on my pump machines daily for rinsing the p/f, cups & for brewing.
Post Reply