Search found 5 matches

by mzimmerm
Mon Apr 18, 2022 7:06 pm
Forum: Maintenance and Repair
Topic: S1 Mini Vivaldi II - Boiler not filling with water
Replies: 8
Views: 1900

Re: S1 Mini Vivaldi II - Boiler not filling with water

You are correct! It was some corrosion in the connector block attached to the fill probe. I cleaned it out and re-stripped the red wire and it works as it should. Thanks for your help. Mike
by mzimmerm
Mon Apr 18, 2022 6:33 pm
Forum: Maintenance and Repair
Topic: S1 Mini Vivaldi II - Boiler not filling with water
Replies: 8
Views: 1900

Re: S1 Mini Vivaldi II - Boiler not filling with water

I unhooked the fill sensor (red) wire and the pump started up. I grounded it out and the pump turned off. I believe I just have a bad fill sensor.
by mzimmerm
Sun Apr 17, 2022 10:48 pm
Forum: Maintenance and Repair
Topic: S1 Mini Vivaldi II - Boiler not filling with water
Replies: 8
Views: 1900

Re: S1 Mini Vivaldi II - Boiler not filling with water

OK. I just performed the "prime procedure" as outlined in the manual. I installed the hot wire back on the boiler element. I powered the unit on and waited for the brew element to come to temp. I then switched the boiler on and red light was flashing. It flashed for about two minutes and t...
by mzimmerm
Sun Apr 17, 2022 6:33 pm
Forum: Maintenance and Repair
Topic: S1 Mini Vivaldi II - Boiler not filling with water
Replies: 8
Views: 1900

Re: S1 Mini Vivaldi II - Boiler not filling with water

Thanks for the reply.

The boiler button is flashing on but I disconnected the hot wire to the element because the boiler is empty and do not want to turn the element on with the boiler empty. If I hook the element up it will start to heat up but the pump does not turn on to fill.
by mzimmerm
Sun Apr 17, 2022 5:40 pm
Forum: Maintenance and Repair
Topic: S1 Mini Vivaldi II - Boiler not filling with water
Replies: 8
Views: 1900

S1 Mini Vivaldi II - Boiler not filling with water

Hi, I have a S1 Mini Vivaldi II. The pump is not coming on to fill the boiler with water. So far the only things I have done is removed the fill probe to clean it and removed hoses to the boiler and blow through them to confirm there were not restricted. Any thoughts on what I could try next? The pu...