Search found 4 matches

by BP10000
Mon Apr 15, 2019 10:34 am
Forum: Maintenance and Repair
Topic: Triac failure signs?
Replies: 1
Views: 4182

Triac failure signs?

I have a new issue with my Mini V2: the steam boiler is beginning to overheat, but only after pulling shots. I can leave it on for hours and it maintains pressure nicely, but after pulling a couple shots and some hot water, I often find that 5 to 15 minutes later the steam boiler pressure will slowl...
by BP10000
Sat Mar 30, 2019 7:16 pm
Forum: Maintenance and Repair
Topic: Mini Vivaldi steam boiler overfill, please help. [ISSUE REOPEN]
Replies: 37
Views: 38614

Re: Mini Vivaldi steam boiler overfill, FIXED!!!

I got it working! After repeating all the previous troubleshooting steps and confirming continuity through all the wires and connections, I had a closer look at the board and found a 100ohm resistor in the sensor ground side that was open circuit. I tested it by manually paralleling another resistor...
by BP10000
Wed Mar 27, 2019 6:49 pm
Forum: General Q&A
Topic: Without Fit, the Form has no Function*
Replies: 1
Views: 5201

Re: Without Fit, the Form has no Function*

I like what you're doing. Hope this helps:

1. The back feet are inset 1 3/4" (back against a flat wall to account for any curvature)
2. Front feet are inset 2"
3. Feet are 1" tall
4. The front of the front feet is 14 1/8" from the back wall
by BP10000
Mon Mar 25, 2019 2:24 pm
Forum: Maintenance and Repair
Topic: Mini Vivaldi steam boiler overfill, please help. [ISSUE REOPEN]
Replies: 37
Views: 38614

Re: Mini Vivaldi steam boiler overfill, please help. [ISSUE REOPEN]

Greetings! I am the new owner of the above machine. I am further troubleshooting and I was wondering if anyone could tell me what the water sensing voltage is supposed to be. I.e. volts between the probe and ground when the water is low. I am getting about 1VDC on open circuit and about 0.2 when the...

Go to advanced search