Search found 13 matches

by mswanson25
Wed Oct 02, 2019 7:11 pm
Forum: Maintenance and Repair
Topic: Steam boiler safety valve failure?
Replies: 6
Views: 9476

Re: Steam boiler safety valve failure?

I can confirm that my issue was resolved by replacing the triac. The boiler was constantly overheating, even though the boiler light was turned off. This was the recommended action by Chris Coffee, as well. The $36 part set me right: https://www.chriscoffee.com/products/triac-vivaldi?variant=1178221...
by mswanson25
Mon Sep 23, 2019 8:14 pm
Forum: Maintenance and Repair
Topic: Steam boiler safety valve failure?
Replies: 6
Views: 9476

Re: Steam boiler safety valve failure?

So far, I'm turning the power on in the morning and it hasn't repeated yet. Chris Coffee also said to take note if the boiler light is solid or flashing next time it happens.

I'll update this thread next time I can catch it happening.
by mswanson25
Thu Sep 19, 2019 4:10 pm
Forum: Maintenance and Repair
Topic: Steam boiler safety valve failure?
Replies: 6
Views: 9476

Re: Steam boiler safety valve failure?

Chas, I noticed today my steam boiler gauge was very much in the red. I turned off the machine, waited sometime, turned back on, disabled the boiler. Then I turned the boiler back on and it stopped overheating. So now it seems that my machine sometimes overheats the boiler and other times doesn't. W...
by mswanson25
Sun Sep 15, 2019 9:24 am
Forum: Maintenance and Repair
Topic: Steam boiler safety valve failure?
Replies: 6
Views: 9476

Steam boiler safety valve failure?

Hello! I have a 2007 vintage and the most awful barking noise is coming from the steam boiler once in a while. I assume that this is the safety valve opening. It does not happen very often and just started last week. When plugged in, I haven't caught the pressure gauge going above 1.2-1.4 bars yet, ...
by mswanson25
Sun Jun 25, 2017 10:04 pm
Forum: Maintenance and Repair
Topic: Filter replacement o ring
Replies: 3
Views: 5302

Re: Filter replacement o ring

Chas. There is many size differences. 3 1/2 to 5 1/4" when I google. Also, it wasn't clear if they are id or od or need a certain width.:)

I rather not take it apart without having the parts, so I'll just order from CC.

Thanks guys.
by mswanson25
Sun Jun 25, 2017 3:03 pm
Forum: Maintenance and Repair
Topic: Filter replacement o ring
Replies: 3
Views: 5302

Filter replacement o ring

Does anyone know the size o ring to buy for the water fillers Chris coffee sells.
by mswanson25
Sat Feb 04, 2017 6:44 pm
Forum: Maintenance and Repair
Topic: Damaged Boiler Temperature Alarm
Replies: 6
Views: 8343

Re: Damaged Boiler Temperature Alarm

Chas. I started to check out my machine and I noticed that one of the leads to the heating element was burned and came out of the spade connector. I cleaned up the wire and crimped on a new connection. Back in business! I'm very thankful I didn't have to plow anymore money into this machine. My wife...
by mswanson25
Tue Jan 31, 2017 8:25 pm
Forum: Maintenance and Repair
Topic: Damaged Boiler Temperature Alarm
Replies: 6
Views: 8343

Re: Damaged Boiler Temperature Alarm

Chas, thanks for the awesome reply. I'll take this weekend to debug this and report back!
by mswanson25
Mon Jan 30, 2017 8:44 pm
Forum: Maintenance and Repair
Topic: Damaged Boiler Temperature Alarm
Replies: 6
Views: 8343

Re: Damaged Boiler Temperature Alarm

I forgot to put down that they are SOLID.

Thank you, Chas.
by mswanson25
Sun Jan 29, 2017 12:04 pm
Forum: Maintenance and Repair
Topic: Damaged Boiler Temperature Alarm
Replies: 6
Views: 8343

Damaged Boiler Temperature Alarm

Hi, I'm getting 19-20-21. Does this mean my steam boiler heating element is broken or the probe or both? Just 3 months ago, I replaced this: https://www.chriscoffee.com/Vivaldi_Coffee_Boiler_Heating_Element_p/7476.htm https://www.chriscoffee.com/La_Spaziale_Temp_Sensor_for_Coffee_Boiler_p/7483.htm N...
by mswanson25
Sun Nov 27, 2016 10:50 am
Forum: Maintenance and Repair
Topic: Broke copper tube off flow meter, part #?
Replies: 4
Views: 7276

Re: Broke copper tube off flow meter, part #?

thanks, chas. I'll call chris coffee and hopefully this will be the last repair. I've had to fix my group heating element and clean the flow meter too. Chris coffee said my group solenoid might be bad too. This machine has been in storage and moved a couple times. I'm surprised the heating element b...
by mswanson25
Sat Nov 26, 2016 10:05 am
Forum: Maintenance and Repair
Topic: Broke copper tube off flow meter, part #?
Replies: 4
Views: 7276

Re: Broke copper tube off flow meter, part #?

That's it. When i search that part number at chris coffee i couldn't find it. Do you know the name of it or I could just call chris coffee on monday.

Thanks!
by mswanson25
Sat Nov 26, 2016 9:04 am
Forum: Maintenance and Repair
Topic: Broke copper tube off flow meter, part #?
Replies: 4
Views: 7276

Broke copper tube off flow meter, part #?

Hi, I was repairing a block in my flow meter. When putting back on the outlet copper tube (that runs to the group boiler) the nut on the tube sheered off. I'm surprised this happened, but I have a 10 year old machine.

Does anyone know the name or part number of this copper tube?

Thanks.